TEKTRONIX TS100 TELSCOUT REPAIRED 4/27/01 - TEKTRONIX SOLD THIS PARTICULAR LINE TO TEMPO!!!!
Cable Tester for Telephone Applications
TelScout® TS100
Features
Twisted Pair and Coax Testing in a Single Unit (Optional)
One-step Setup
15 km Fault Location Capability
Rugged - Survives 2 m Drop
Single-button Zoom Function
Pair Comparison Mode
Splits/Crosstalk Mode
Internal Storage for 20 Waveforms and Notes
Serial Printer Output for Stored or Displayed Waveforms
Online Tutorials
Large Backlit Display
Applications
Twisted Pair Telephony/Maintenance and Repair
Intermittent Fault Location
Wet Cable Identification
Measure Distance to Load Coil
Identify Opens, Shorts and Splits on POTS Plant
If your job is to find faults on telephone twisted pair cable, the Tektronix TelScout TS100 is built for you. Designed specifically for telephone local loop applications, the TS100 applies the newest technology to provide both ease of use and telephony performance that cannot be found in any other TDR.
The TS100 is designed for ease-of-use you'll spend less time operating the TDR, and more time repairing faults. Simply select the cable type to be tested and the TS100 does the rest. Impedance, Vp, gain, pulse width, and vertical position are automatically selected and adjusted as you scan the cable. Just move the cursor to the fault to pinpoint its location.
On the performance side, the TS100 employs optimized pulsing and sampling, coupled with advanced filtering and signal processing techniques, to insure the maximum measurement range. That way, you'll always have a clean waveform for easier fault interpretation.
Call to see if units in stock include option 1 for Coax testing!!
Short Pulse and Coax Option
The short pulse Option 01 provides a 5 ns pulse width for close-in resolution. Faults as near as 3 ft. from the pedestal can be located with ease.
Option 01 also includes a coaxial cable setup menu and an adapter cable. This enables you to locate faults in coaxial cables used in today's emerging broadband systems.
Best of all, you get all this performance in the industry's most rugged TDR package. Come snow, rain, heat and humidity, the TS100 keeps working, because you have to.
Cable Tester for Telephone Applications
TelScout® TS100
Characteristics
Test Signal Output -
Standard: 1/2 Sine, balanced.
Opt. 01: 1/2 Sine.
Amplitude -
Standard: 20 ns: 8 V into 105 Ohm.
All Other Pulse Widths: 20 V into 105 Ohm.
Opt. 01: 5 ns: 2.5 V into 105 Ohm.
20 ns: 1 V into 105 Ohm.
All Other Pulse Widths: 4 V into 105 Ohm.
Output Impedance -
Standard: 105 Ohm.
Opt. 01: 105 Ohm.
Pulse Widths -
Standard: 20 to 3,000 ns.
Opt. 01: 5 to 3,000 ns.
Input Protection -
±400 V, DC + peak AC, to a maximum of 440 Hz.
Maximum Range -
Standard: 15,000 m (45,000 ft.), depending on cable type and condition.
Opt. 01: 10,000 m (30,000 ft.) depending on cable type and condition.
Display Resolution -
0.33% of selected range, 4.5 cm (0.15 ft.) minimum, on 640 x 200 high-resolution backlit LCD.
Display Ranges - Eleven display ranges plus single-button expand window. Ranges are user definable in manual mode.
Filter - High pass, cutoff frequency 150 kHz, user selectable.
Amplifier- 5 mV reflection produces a full-screen vertical deflection.
Gain - 0 to 63 dB.
Waveform Storage - Up to 20 waveforms with notes.
Horizontal Accuracy -
0 to 5,000 m: ±1 m ± uncertainty in Vp.
5,000 to 15,000 m: ±2 m ± uncertainty in Vp.
0 to 2,000 ft.: ±2 ft. ± uncertainty in Vp.
2,000 to 10,000 ft.: ±3 ft ± uncertainty in Vp.
10,000 to 20,000 ft.: ±4 ft. ± uncertainty in Vp.
Serial Interface - 9-Pin D-type serial connector.
General Characteristics
Environmental
Temperature -
Operating: -15°C to +60°C.
Nonoperating: -20°C to +65°C.
Humidity: 95% RH, non-condensing.
Shock: (test specification) Survives drop of 2 m to concrete in standard soft case.
EMI Emissions: FCC part 15, subpart J, class A; VFG243 and EN55022.
Power
Mains Operation -
Voltage Ranges: 110 V, 220 V, 240 V with appropriate AC to DC adapter.
Battery Operation -
Operating Time: 8 hrs. continuous.
Battery Saver: Selectable for 5 to 30 minutes
or disabled.
Safety - UL1244, CSA231.
Physical Characteristics
Dimensions cm in.
Height 30.0 12.0
Width 25.0 10.0
Depth 9.0 3.5
Weight kg lb.
Net 3.0 6.4